AVR
Showing all 14 results
-
AVR, Generator
DTA-225 Consealed AVR Automatic Voltage Regulator For Generator
Model No DTA-225 Consealed
- This model is specially designed to protect against moisture and shocks
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 25A DC
- Continuous 13A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 20 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Requires Only 2V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Low Cost
SKU: n/a -
AVR, Generator
DTA-525 Consealed AVR Automatic Voltage Regulator For Generator
Model No DTA-525 Consealed
- This model is specially designed to protect against moisture and shocks
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 25A DC
- Continuous 13A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 20 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Requires Only 2V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Low Cost
SKU: n/a -
AVR, Generator
DTA-625 AVR Automatic Voltage Regulator For Generator
Model No DTA-625
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 25A DC
- Continuous 13A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 25 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Requires Only 4V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Repairable
- Low Cost
SKU: n/a -
AVR, Generator
DTA-625 Consealed AVR Automatic Voltage Regulator For Generator
Model No DTA-625 Consealed
- This model is specially designed to protect against moisture and shocks
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 25A DC
- Continuous 13A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 25 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Suitable for 10 KVA 30 KVA Slip Ring Generator
- Requires Only 4V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Low Cost
SKU: n/a -
AVR, Generator
DTA-695 AVR 100A Automatic Voltage Regulator For Generator
Model No DTA-695
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 100A DC
- Continuous 70A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 25 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Suitable for 10 KVA 200 KVA Slip Ring Generator
- Requires Only 4V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Repairable
- Low Cost
SKU: n/a -
AVR, Generator
DTA-695 AVR 100A Module type Automatic Voltage Regulator For Generator
Model No DTA-695 Module
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 100A DC
- Continuous 70A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 25 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Suitable for 10 KVA 200 KVA Slip Ring Generator
- Requires Only 4V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Repairable
- Low Cost
SKU: n/a -
AVR, Generator
GAVR-12A GAVR 12A AVR for Generator Automatic Voltage
TECHNICAL DATA:
Voltage Set-up:The voltage set up when the remnant magnetism greater than 4V 25Hz
Input power Supply:AC 160~260V 50/60Hz
Maximum Output: DC 5A 95V(when the voltage reaches AC 240V)
Frequency Compensation:Built-in low speed protective circuit.INPUT:
Voltage Jumper selectable
95-132V ac or 190-264 Hz nominal
Frequency 50-60 Hz nominal
OUTPUT:
Voltage max 90V dc at 207V ac input
Current continuous 2A dc
Intermittent 5A for 10 secs
Resistance 20 ohms minimum
REGULATION: +/-1%This is one kinds of currency AVRs for brushless generators in the world.
TECHNICAL DATA:
INPUT:
Voltage :160-260V AC
Frequency :50-60 Hz nominalSKU: n/a -
AVR, Generator
GAVR-15A Automatic Voltage Regulator
- SENSING INPUT: Voltage : 220/400V AC
- POWER INPUT: Voltage : 100-260V AC MAX; Frequency : 50-60 Hz nominal
- OUTPUT: Voltage : max 90V DC at 240V AC input; Current : continuous 6A,Intermittent 12A for 10 secs; Resistance : Min.10Ω Max.100Ω
- VOLTS REGULATION: < ± 0.5% (with 4% engine governing)
- VOLTAGE BUILD-UP: Residual volts at AVR terminal > 5 VAC
- EXTERNAL VOLTS ADJUSTMENT: ± 7% with 1K Ω, 1 Watt trimmer
- UNIT POWER DISSIPATION: MAX 8 Watt
- THERMAL DRIFT: 0.05% per °C change in AVR ambient temperature
- UNDER FREQUENCY PROTECTION: 60 Hz system presets knee point at 57Hz; 50Hz system presets knee point at 47Hz
SKU: n/a -
AVR, Generator
Leroy Somer AVR R438 Automatic Voltage Regulator For Generator
Input voltage0-110V: 95-140V,
0-220V: 170-260V, 0-380V: 340-520V,
frequency50/60 Hz
,Rated overload current8 A up to 10 sec,
External voltage regulation0.47KΩ/0.5W: ±5%, 1.5KΩ/0.5W: ±10%.Operating temperaturefrom -20°С to +70°С,
Dimensions140x124x50 mm.Weight750
Voltage Regulation ±0.5% Remote voltage adjustment range ±0.5% Short circuit capability 3 x Irated for 10 seconds Standard power supply AREP or PMG Rated overload current 8 A – 10 s Voltage sensing 5 VA isolated via transforme 0-110V terminals 95 to 140V 0-220V terminals 170 to 260V 0-380V terminals 340 to 520V Voltage regulation ± 1% Current sensing C.T.2.5VA cl1,secondary 1 A Voltage sensing 95~140 volts (50/60 Hz) 170~260 volts (50/60 Hz) 340~520 volts (50/60 Hz) Fit for 1000 series generator 2000 series generator 3000 series generator SKU: n/a -
AVR, Generator
R230 AVR Automatic Voltage Regulator for Single-Phase Two-Wire Generator
- 100% brand new and high quality.
- This product is a AVR(Automatic Voltage Regulator) for brushless alternator with adjustable voltage.
- The regulator monitors the exciter excitation current as a function of the alternator output voltage.
- Very simple in design, the alternator with shunt excitation has no sustaining short-circuit capacity.
- Made with flame retardant and heat resisting material, stable and reliable to use.
- Input
Voltage 85-139 VAC
Frequency 50-60 Hz nominal
Output
Voltage max 75 V DC at 100V AC input
Current continuous 4A DC
Intermittent 8A
Resistance 15 ohms minimum
Regulation +/- 0.5%
SKU: n/a -
AVR, Generator
R448 AVR for Leroy Somer | Automatic Voltage Regulator For Generator
- Normal AVR supply power:2 auxiliary windings (X1, X2, ans Z, Z2)
- Shunt supply: 150V – 5060Hz Rated overload current:10A, 10s.
- Electronic built- in )overload, short circuit, and loss of sensing) protecting: If excitation current raises over 10 amps for more then 10 seconds, excitation current will drop automatically to about 1A.
- To reset AVR protection, the generator must be stopped )or by cutting supply voltage to the AVR). Protection of power inputs by fuses F1
- Voltage sensing: 5VA insulated transformer with input voltage taps at: Terminals 0 – 110V = 95 to 140V. Terminals 0 – 220V = 170 to 260V. Terminals 0 – 380V = 340 to 520V
SKU: n/a -
AVR, Generator
R449 Automatic Voltage Regulator AVR R449 for Leroy Somer Generator
Specifications:
- Normal AVR supply power:2
- Auxiliary windings(X1,X2,and Z,Z2)
- Shunt supply:150V-50/60Hz
- Rated overload current:10A,10s
- Electronic built-in(overload,short circuit,and loss of sensing)
- Protection of power inputs by fuses F1
- Voltage Sensing:5VA insulated transformer with input voltage taps at:
- Terminals 0-110V=95 to 140V
- Terminals 0-220V=170 to 260V
- Terminals 0-380V=340 to 520V
SKU: n/a -
AVR, Generator
SX460 AVR – Automatic Voltage Regulator Imported
- SX460 AVR – Automatic Voltage Regulator – Exact Generic Replacement.
- INPUT: Voltage: Jumper selectable 95-132V ac or 190-264V ac, Frequency: 50-60 Hz nominal, Phase: 1
- OUTPUT: Voltage: Max 90V dc at 207V ac input, Current: Continuous 4 A dc, Intermittent 6 A for 10 secs, Resistance: 15 ohms minimum.
- Regulation: +/-1.0% * Thermal drift: 0.05% per deg. C change in AVR ambient.
- Unit power dissipation: 10 watts maximum – Build up voltage:4 Volts @ AVR terminals.
- INPUT
Voltage: 220V AC Jumper selectable
Frequency: 50-60Hz nominal
Phase: 1OUTPUT
Voltage: max 90V DC at 207V AC Input
Current: continuous 4 A DC
Resistance: 15 ohms minimum
SKU: n/a -
AVR, Generator
Sx460-Red Generator Spare Parts Voltage Regulator Imported
SPECIFICATIONProduct NameSX460SENSING/POWER INPUT VOLTAGE120(90-132VAC) or 240(190-264VAC), 1 phase 2 wireMAGNETIC FIELD OUTPUT VOLTAGEmax 90VDC at 207VAC inputCurrentcontinuous 4A, intermittent 10A within 10 secondsPRESSURE REGULATING ACCURACY<+/-1%RMS with 4% engine governingSKU: n/a