AMF / ATS Controller, Generator, Genset Starting Module
DKG105 DATAKOM Generator Automatic Mains Failure control panel
AMF / ATS Controller, Generator, Genset Starting ModuleDKG105 DATAKOM Generator Automatic Mains Failure control panel
DKG-105 AUTOMATIC MAINS FAILURE UNIT
The DKG-105 automatic mains failure unit is a microprocessor based digital unit offering all functions needed for the automatic control of a genset.
The unit fits into a standard 72x72mm panel meter opening and offers a very cost effective and
space saving solution for the basic genset control.
In automatic mode, the unit monitors 3 phases of the mains voltage and controls the automatic starting, stopping and load transfer of the generator.
Once the generator is running, the device monitors the internal protections and external fault inputs.
DKG-105 provides a full set of digitally adjustable timers and threshold levels. Also the relay configuration is programmable, enabling the control of various types of engines, including gasoline engines.
The programs may be modified by the customer via pushbuttons on the unit, and do not require an external unit.
Automatic engine starting and stopping Gas engine support
Automatic mains failure monitoring
Automatic load transfer
Automatic shutdown on fault condition
Test mode available
Survives cranking dropouts
Digital engine run-hours display
Provision for energize to stop, preheat & choke outputs
Mains phases voltage limits checking
Generator phase voltage limits checking
SKU: n/a -
AMF / ATS Controller, Generator, Genset Starting Module
DSE 704 Auto Start Generator Control Panel Alternator
AMF / ATS Controller, Generator, Genset Starting ModuleDSE 704 Auto Start Generator Control Panel Alternator
Features:
- The automatic (utility) sector provides monitoring
- Automatic shutdown when fault conditions are detected
- Manual start
- Engine preheating
- Motor monitoring and protection functions
- Protected semiconductor outputs (PSS)
- Front panel mounting
- Front panel programming
- Tamper-proof engine hour counter
- Remote start
- LED indicators
- Configurable timers
- Configurable outputs
- Single-phase / three-phase hand detection
SKU: n/a -
-
AMF / ATS Controller, Generator
DTA-110 Generator AMF/ATS Control Card With Heater Disele Generator
- Auto Main Failure and Automatic load transfer unit
- Microprocessor controled
- The Heater Turns on for About Six Seconds Before Turning on the Self
- Self On/Off Time Setting
- Genset On Load Time & Genset Off Load Time
- Main On Load Time
- Generator Cool Down Time Built in 40 Seconds
- Failed To Start Indication LED
- Excellent Ability to Start and Stop the Generator
- DC Supply: 12 Volts, (+) and (-) Terminals.
- Indicators to show card performance
- Capability to transfer loads without DC 12 volts
- There is an extra Switchs to start and stop the generator manually
SKU: n/a -
AMF / ATS Controller, Generator
DTA-126 Genrator AMF Card
- DTA126 unit which is specially designed for Genset.
- It is used to start and stop the Genset in automatic or manual mode auto/manual switch on the panel. DTA126 is an Reliable Modle.
- DTA126 Just Auto Main failure Uint.
- When Main shutdown DTA126 satart the genrator & After Main comeback Stop the Genrator.
- DTA126 have Three variables for Self On/off & Main On time settings .
- DC Supply: 12 volts, (+) and (-) terminals.
SKU: n/a -
AMF / ATS Controller, Generator
DTA-127 Generator AMF/ATS Control Card
Auto Main Failure and Automatic load transfer unit
- Main Shutdown Time Adjustable
- Self On/Off Time Setting
- Genset On Load Time & Genset Off Load Time
- Main On Load Time
- Generator Cool Down Time
- Failed To Start Indication LED
- Excellent Ability to Start and Stop the Generator
- DC Supply: 12 Volts, (+) and (-) Terminals.
- Indicators to show card performance
- Capability to transfer loads without DC 12 volts
SKU: n/a -
AMF / ATS Controller, Generator
DTA-150 Generator AMF/ATS Control Card
Auto Main Failure and Automatic load transfer unit
- Microprocessor controled
- Self On/Off Time Setting
- Genset On Load Time & Genset Off Load Time
- Main On Load Time
- Generator Cool Down Time Built in 25 Seconds
- Failed To Start Indication LED
- Excellent Ability to Start and Stop the Generator
- DC Supply: 12 Volts, (+) and (-) Terminals.
- Indicators to show card performance
- Capability to transfer loads without DC 12 volts
- Negative Voltage out from the Choke to Turn off the Generator
- There is an extra Switch to start and stop the generator manually
SKU: n/a -
AMF / ATS Controller, Generator
DTA-161 Genrator AMF / Auto Main Failure Card
- DTA161 unit which is specially designed for Genset.
- It is used to start and stop the Genset in automatic or manual mode auto/manual switch on the panel. DTA161 is an Reliable Modle.
- DTA161 Just Auto Main failure Uint.
- When Main shutdown DTA161 satart the genrator & After Main comeback Stop theGenrator
- DTA161 have Three variables for Self On/off & Choke Off time settings .
- DC Supply: 12 volts, (+) and (-) terminals.
- Operating Voltage 220V
SKU: n/a -
AMF / ATS Controller, Generator
DTA-182 Generator AMF/ATS Control Card
Auto Main Failure and Automatic load transfer unit
- Microprocessor controled
- Self On/Off Time Setting
- Genset On Load Time & Genset Off Load Time
- Main On Load Time
- Generator Cool Down Time Built in 25 Seconds
- Failed To Start Indication LED
- Excellent Ability to Start and Stop the Generator
- DC Supply: 12 Volts, (+) and (-) Terminals.
- Indicators to show card performance
- Negative Voltage out from the Choke to Turn off the Generator
- There is an extra Switch to start and stop the generator manually
SKU: n/a -
-
AMF / ATS Controller, Generator
DTA-201 Generator AMF/ATS Control Card With Heater & Low Oil Pressure & High Temperature Switch Safety
AMF / ATS Controller, GeneratorDTA-201 Generator AMF/ATS Control Card With Heater & Low Oil Pressure & High Temperature Switch Safety
Auto Main Failure and Automatic load transfer With Heater & Low Oil Pressure & High Temperature Switch Safety
- Microprocessor controled
- The Heater Turns on for About 9 Seconds Before Turning on the Self
- Self On/Off Time Setting
- Genset On Load Time & Genset Off Load Time
- Main On Load Time
- Generator Cool Down Time Built in 14 Seconds
- Failed To Start Indication LED
- Excellent Ability to Start and Stop the Generator
- DC Supply: 12 Volts, (+) and (-) Terminals.
- Indicators to show card performance
- Capability to transfer loads without DC 12 volts
- There is an extra Switch to start and stop the generator manually
SKU: n/a -
AMF / ATS Controller, Generator
DTA-210 AMF/ATS 2 Wapda & 1 Generator Automatic Load Transfer and Generator Start/Stop Unit
AMF / ATS Controller, GeneratorDTA-210 AMF/ATS 2 Wapda & 1 Generator Automatic Load Transfer and Generator Start/Stop Unit
- Aoutmatic 2 main Lines And Generator Control Card
- This card is Specially Designed to Control Two WAPDA Meters and One Generator
- Meter 1 and Meter 2 automatically switch with time Delay Setting
- In case of both line shutdown, it starts the generator itself and shifts the load to the generator.
- If in-wapda 2 comes on while the generator is running, it shuts down the generator and turns it into Metter 2.and shifts the load to the Metter 2.
- In case of both Line 1 and Line 2 coming, the load of Line 1 will be transferred automatically
- Variables to Onload line one, line two, and line three
- Self On/Off Time Setting
- Genset On Load Time & Genset Off Load Time
- Main On Load Time
- Generator Cool Down Time
- Failed To Start Indication LED
- Excellent Ability to Start and Stop the Generator
- DC Supply: 12 Volts, (+) and (-) Terminals.
- Indicators to show card performance
- Capability to transfer loads without DC 12 volts
SKU: n/a -
AVR, Generator
DTA-225 Consealed AVR Automatic Voltage Regulator For Generator
Model No DTA-225 Consealed
- This model is specially designed to protect against moisture and shocks
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 25A DC
- Continuous 13A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 20 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Requires Only 2V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Low Cost
SKU: n/a -
AMF / ATS Controller, Generator, Genset Starting Module
DTA-264 Generator AMF/ATS Control Module With Heater & Low Oil Pressure & High Temperature, Low High Voltage, Over Under frequency Safety
AMF / ATS Controller, Generator, Genset Starting ModuleDTA-264 Generator AMF/ATS Control Module With Heater & Low Oil Pressure & High Temperature, Low High Voltage, Over Under frequency Safety
- Auto Main Failure and Automatic load transfer With Safety
- Microprocessor controled
- Manual start Optional
- Front panel mounting
- Front panel programming
- Configurable timers
- Ldc Display
- Main Shutdown timer
- Heater On Timer
- Crank On Timer
- Crank Rest Timer
- Generator on Load Timer
- Size : 165mm , 125mm , 45 mm
- Penal Cutout Size: 113mm X 152mm
- Generator Off Load Timer
- Main On Load Timer
- Generator Cooling Timer
- Choke On Timer
- Frecuency Delay Timer
- Frecuency High Limit
- Frecuency Lower Limit
- Warmup Timer
- Numebr of Start Attempts
- Main Voltage High Limit
- Main Voltage Lower Limit
- Generator Over Voltage high Limit
- Generator Under Voltage Limit
- DC Supply: 12V & 24volts, (+) and (-) terminals.
SKU: n/a -
AVR, Generator
DTA-525 Consealed AVR Automatic Voltage Regulator For Generator
Model No DTA-525 Consealed
- This model is specially designed to protect against moisture and shocks
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 25A DC
- Continuous 13A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 20 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Requires Only 2V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Low Cost
SKU: n/a -
AVR, Generator
DTA-625 AVR Automatic Voltage Regulator For Generator
Model No DTA-625
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 25A DC
- Continuous 13A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 25 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Requires Only 4V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Repairable
- Low Cost
SKU: n/a -
AVR, Generator
DTA-625 Consealed AVR Automatic Voltage Regulator For Generator
Model No DTA-625 Consealed
- This model is specially designed to protect against moisture and shocks
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 25A DC
- Continuous 13A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 25 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Suitable for 10 KVA 30 KVA Slip Ring Generator
- Requires Only 4V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Low Cost
SKU: n/a -
AVR, Generator
DTA-695 AVR 100A Automatic Voltage Regulator For Generator
Model No DTA-695
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 100A DC
- Continuous 70A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 25 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Suitable for 10 KVA 200 KVA Slip Ring Generator
- Requires Only 4V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Repairable
- Low Cost
SKU: n/a -
AVR, Generator
DTA-695 AVR 100A Module type Automatic Voltage Regulator For Generator
Model No DTA-695 Module
- Inpt Voltage: 220V AC
- Phase: Single 1
- Frecuency: 50hz – 60Hz
- Output Voltage: 0V To 90V Dc Maximum
- Current Max: 100A DC
- Continuous 70A-Dc Excitation Current
- Controls: Volt , Stab
- Quick response ( 25 ms )
- Thyristor Control Technology
- Suitable for 10 KVA 1000 KVA Brushless Generator
- Suitable for 10 KVA 200 KVA Slip Ring Generator
- Requires Only 4V-AC Residual Voltage to Buildup Alternator Voltage
- Easy to Install
- Repairable
- Low Cost
SKU: n/a -
AVR, Generator
GAVR-12A GAVR 12A AVR for Generator Automatic Voltage
TECHNICAL DATA:
Voltage Set-up:The voltage set up when the remnant magnetism greater than 4V 25Hz
Input power Supply:AC 160~260V 50/60Hz
Maximum Output: DC 5A 95V(when the voltage reaches AC 240V)
Frequency Compensation:Built-in low speed protective circuit.INPUT:
Voltage Jumper selectable
95-132V ac or 190-264 Hz nominal
Frequency 50-60 Hz nominal
OUTPUT:
Voltage max 90V dc at 207V ac input
Current continuous 2A dc
Intermittent 5A for 10 secs
Resistance 20 ohms minimum
REGULATION: +/-1%This is one kinds of currency AVRs for brushless generators in the world.
TECHNICAL DATA:
INPUT:
Voltage :160-260V AC
Frequency :50-60 Hz nominalSKU: n/a -
AVR, Generator
GAVR-15A Automatic Voltage Regulator
- SENSING INPUT: Voltage : 220/400V AC
- POWER INPUT: Voltage : 100-260V AC MAX; Frequency : 50-60 Hz nominal
- OUTPUT: Voltage : max 90V DC at 240V AC input; Current : continuous 6A,Intermittent 12A for 10 secs; Resistance : Min.10Ω Max.100Ω
- VOLTS REGULATION: < ± 0.5% (with 4% engine governing)
- VOLTAGE BUILD-UP: Residual volts at AVR terminal > 5 VAC
- EXTERNAL VOLTS ADJUSTMENT: ± 7% with 1K Ω, 1 Watt trimmer
- UNIT POWER DISSIPATION: MAX 8 Watt
- THERMAL DRIFT: 0.05% per °C change in AVR ambient temperature
- UNDER FREQUENCY PROTECTION: 60 Hz system presets knee point at 57Hz; 50Hz system presets knee point at 47Hz
SKU: n/a -
AVR, Generator
Leroy Somer AVR R438 Automatic Voltage Regulator For Generator
Input voltage0-110V: 95-140V,
0-220V: 170-260V, 0-380V: 340-520V,
frequency50/60 Hz
,Rated overload current8 A up to 10 sec,
External voltage regulation0.47KΩ/0.5W: ±5%, 1.5KΩ/0.5W: ±10%.Operating temperaturefrom -20°С to +70°С,
Dimensions140x124x50 mm.Weight750
Voltage Regulation ±0.5% Remote voltage adjustment range ±0.5% Short circuit capability 3 x Irated for 10 seconds Standard power supply AREP or PMG Rated overload current 8 A – 10 s Voltage sensing 5 VA isolated via transforme 0-110V terminals 95 to 140V 0-220V terminals 170 to 260V 0-380V terminals 340 to 520V Voltage regulation ± 1% Current sensing C.T.2.5VA cl1,secondary 1 A Voltage sensing 95~140 volts (50/60 Hz) 170~260 volts (50/60 Hz) 340~520 volts (50/60 Hz) Fit for 1000 series generator 2000 series generator 3000 series generator SKU: n/a -
AVR, Generator
R230 AVR Automatic Voltage Regulator for Single-Phase Two-Wire Generator
- 100% brand new and high quality.
- This product is a AVR(Automatic Voltage Regulator) for brushless alternator with adjustable voltage.
- The regulator monitors the exciter excitation current as a function of the alternator output voltage.
- Very simple in design, the alternator with shunt excitation has no sustaining short-circuit capacity.
- Made with flame retardant and heat resisting material, stable and reliable to use.
- Input
Voltage 85-139 VAC
Frequency 50-60 Hz nominal
Output
Voltage max 75 V DC at 100V AC input
Current continuous 4A DC
Intermittent 8A
Resistance 15 ohms minimum
Regulation +/- 0.5%
SKU: n/a -
AVR, Generator
R448 AVR for Leroy Somer | Automatic Voltage Regulator For Generator
- Normal AVR supply power:2 auxiliary windings (X1, X2, ans Z, Z2)
- Shunt supply: 150V – 5060Hz Rated overload current:10A, 10s.
- Electronic built- in )overload, short circuit, and loss of sensing) protecting: If excitation current raises over 10 amps for more then 10 seconds, excitation current will drop automatically to about 1A.
- To reset AVR protection, the generator must be stopped )or by cutting supply voltage to the AVR). Protection of power inputs by fuses F1
- Voltage sensing: 5VA insulated transformer with input voltage taps at: Terminals 0 – 110V = 95 to 140V. Terminals 0 – 220V = 170 to 260V. Terminals 0 – 380V = 340 to 520V